Technical Specs
| GENERAL | ||
| DIAGNOSTICS | Full system self-test at startup | |
| UPS BYPASS | Automatic on overload or UPS failure | |
| PARALLEL FOR REDUNDANCY | Yes, using Powerware Hot Sync technology and capacity | |
| DIMENSIONS AND WEIGHTS | See product brochure | |
| OVERLOAD (NORMAL OPERATION) | 150% for 5 sec / 125% for 1 min (online), 110% for 10 min | |
| ELECTRICAL INPUT | ||
| NOMINAL INPUT VOLTAGE | 9355 (10 – 15 kVA):
208V/120V or 220V/127V three-phase 400V models also available |
9355 (20 – 30 kVA):
208V/120V, 220V/127V +10, -15% 480V/277V, 600V (480+600 with transformer) 400V models also available |
| INPUT VOLTAGE RANGE | -15%, +10% from nominal at 100% load without depleting battery | |
| OPERATING FREQUENCY | 50/60 Hz (45 to 65 Hz) | |
| INPUT POWER FACTOR | 9355 (10 – 15 kVA):
>0.99 typical, >0.96 frequency converter |
9355 (20 – 30 kVA):
0.99 typical |
| INPUT CURRENT DISTORTION | 5% THD | |
| ELECTRICAL OUTPUT | ||
| NOMINAL OUTPUT VOLTAGE | 9355 (10 – 15 kVA):
208/120, 220/127 Vac |
9355 (20 – 30 kVA):
208/120, 220/120 Vac |
| OUTPUT VOLTAGE REGULATION | 9355 (10 – 15 kVA):
±1% static; ±5% dynamic at 100% resistive load change, <1 ms response time |
9355 (20 – 30 kVA):
±1% static; ±4% dynamic with 100% step load recovery within 1 ms response time |
| EFFICIENCY | 91%, typical | |
| HEAT DISSIPATION (BTU/HR) | 10 kVA models: 3,798 @ 208V and 220V input 6,294 @ 480V and 600V (with input isolation transformer)15 kVA models: 5,122 @ 208V and 220V input 8,134 @ 480V and 600V (with input isolation transformer) |
20 kVA models: 6,762 @ 208V and 220V input 10,450 @ 480V and 600V (with input isolation transformer)30 kVA models: 9,220 @ 208V and 220V input 13,831 @ 480V and 600V (with input isolation transformer) |
| BATTERY | ||
| BATTERY TYPE | 9 Ah, sealed, lead-acid, maintenance-free | |
| BATTERY RUNTIME | See product brochure | |
| BATTERY MANAGEMENT | ABM technology | |
| BATTERY REPLACEMENT | Field-replaceable | |
| CHARGER | 9355 (10 – 15 kVA):
Default is 3.4A per battery string. Charger current is configurable from 0.5A to 25A per string with an overall maximum of 34A (limited by input current) |
9355 (20 – 30 kVA):
Default is 8A |
| START-ON-BATTERY | Allows start of UPS without utility input | |
| COMMUNICATIONS | ||
| LCD DISPLAY | Graphical LCD with blue backlight | |
| LEDS | (4) LEDs for notice and alarm | |
| AUDIBLE ALARMS | Yes | |
| COMMUNICATION PORTS | (1) RS-232, (1) relay contact, (1) REPO, (2) environmental input | |
| COMMUNICATION SLOTS | (2) X-Slot communication bays | |
| POWER MANAGEMENT SOFTWARE | Bundled software suite CD | |
| ENVIRONMENTAL | ||
| OPERATING TEMPERATURE | 50–104ºF (10–40ºC), 45ºC with 7.5% derating; Optimal battery performance: 77ºF (25ºC) | |
| STORAGE TEMPERATURE | 32–77ºF (0–25ºC); Recommended battery storage: 59–77ºF (15–25ºC) | |
| RELATIVE HUMIDITY | 9355 (10 – 15 kVA):
0–95%, non-condensing |
9355 (20 – 30 kVA):
5–95%, non-condensing |
| AUDIBLE NOISE | 9355 (10 – 15 kVA):
<56 dBA at 1 meter (noiseless room) typical |
9355 (20 – 30 kVA):
<58 dBA at 1 meter depending on load |
| ALTITUDE | 9355 (10 – 15 kVA):
9,843 ft. (3000m) without derating |
9355 (20 – 30 kVA):
<3000m |
| CERTIFICATIONS | ||
| SAFETY CERTIFICATIONS | UL1778 5th Edition, CSA C22.2 No. 107.3-14, NOM-NYCE | |
| EMC COMPLIANCE | 47 CFR Part 15/ICES-003 Class A | |
| QUALITY | ISO 9001:2015, ISO 14001:2004 | |
| SURGE | ANSI C62.41 Category B3, IEC 61000-4-5 | |
| MARKINGS | cULus, NOM-NYCE | |
| POWER DISTRIBUTION MODULE WITH MECHANICAL BYPASS SWITCH | See product brochure | |
| OPTIONS | See product brochure | |
| BUILT-IN CONNECTIVITY OPTIONS | See product brochure | |