Liebert APM 60K-F 60kVA / 45 kW 208 volt UPS System

Price: $20,000.00

Fields marked with an * are required

Liebert APM 60K-F 60kVA / 60 kW 208 volt UPS System will provide redundancy and scalability using innovative Liebert modular power core assemblies. Each includes distributed intelligence and scalable power in one common module.

SKU: Liebert APM 60kVA Categories: , , , , ,
Brand: Liebert

Liebert APM 60K-F 60kVA / 60 kW 208 volt UPS System will provide redundancy and scalability using innovative Liebert modular power core assemblies. Each includes distributed intelligence and scalable power in one common module. This technology allows configuration of a completely redundant power and control system, sized to match the capacity of the protected equipment. When power requirements change, capacity is easily added – without increasing the system footprint. The Liebert APM UPS scales from 15 to 45kW in a cabinet configuration that includes internal batteries, or from 15 to 90kW in 15kW increments in a configuration that reserves a cabinet for capacity that is paired with an external battery cabinet. This approach allows for right-sizing of the UPS, resulting in improved energy efficiency and reduced power expenditures.

Liebert APM 60K-F 60kVA / 60 kW 208 volt UPS System in stock with a Maintenance bypass / power distribution cabinets and two matching battery cabinets. We can provide the appropriate battery from our large new battery inventory or source any brand battery you prefer. We only provide high rate batteries designed for use in UPS equipment.

Liebert APM 60K-F 60kVA / 60 kW 208 volt UPS System Bypass Distribution Cabinet External maintenance bypass provides complete serviceability while load is running on bypass utility power Integral distribution saves space and cost Kirk-key interlock ensures proper operation 65 kAIC rating meets high electrical withstand requirements.

THIS UPS SYSTEM CAN BE CONFIGURED UP TO 90 kVA / 90 kW. Each 15 kva increase is approximately $6,000.00. The 90 kVA / 90 kW configuration for the UPS would be $32,000.00. All pricing includes the bypass / distribution cabinet. Battery systems are sold separately.

Input

• Voltage Configuration for Standard Unit- 208V, three-phase, four-wire plus ground
• Voltage Range- +15%, -20% of nominal without derating
• Frequency- 40-70Hz
• Power Factor- 99 full load, 0.98 half load
• Inrush Current- UPS inrush current not to exceed 1.5 times rated input current. Maintenance bypass and distribution cabinet inrush current not to exceed 8 times rated input current.
• Current Limit- 140% of nominal AC input current maximum
• Current Distortion- <3% reflected THD maximum at full load
• Surge Protection- Sustains input surges without damage per criteria listed in IEC 1000-4-5

Output, UPS Inverter

• Voltage Configuration- three-phase, 4-wire plus ground
• Voltage Regulation:
-±1% three-phase RMS average for a balanced three-phase load for the combined variation effects of input voltage, connected load, battery voltage, ambient temperature and load power factor
-±5% three-phase RMS average for a 100% unbalanced load for the combined variation effects of input voltage, connected load, battery voltage, ambient temperature and load power factor
• Frequency- ±0.1% (single Liebert FlexPower assembly), ±0.25% (six Liebert FlexPower assemblies)
• Frequency Slew Rate- Selectable from 0.1Hz/sec to 3.0Hz/sec maximum for single unit
• Phase Balance- 120 degrees ±1 degree for balanced load, 120 degrees ±1.5 degrees for 100% unbalanced load
• Voltage Distortion- <1% total harmonic distortion (THD) for linear loads, <5% THD for 100% nonlinear loads (3:1 crest factor) without kVA/kW derating
• Load Power Factor Range- 7 lagging to 0.9 leading without derating
• Output Power Rating- 99 full load. 0.98 half load
• Overload Capability- 110% for 60 minutes, 125% for 10 minutes, 150% for 60 seconds
• Voltage Transient Response- 100% load step, ±5.0%
• Transient Recovery Time- to within 5% of steady state output voltage within half a cycle
• Voltage Unbalance- 100% unbalanced load, ±5%

Environmental

• Operating Ambient Temperature- UPS Module: 32°F to 104°F (0°C to 40°C), Battery: 77°F ±9°F (25°C ±5°C)
• Storage/Transport Ambient Temperature- UPS Module: -4°F to 158°F (-20°C to 70°C), Battery: -4°F to 86°F (-20°C to 30°C)
• Relative Humidity- 0 to 95%, non-condensing
• Altitude- Operating: 3300 ft. (1000m) above sea level; derate power by 1% per 330 ft. (100m) between 3300 and 6000 ft (1000m and 2000m).Storage/Transport: to 40,000 ft. (12,200m) above mean sea level.
• Audible Noise- 56 dB (45kW/kVA models), 60 dB (90kW/kVA models)